Translate:

Search Results


501 to 550 of 1822 Models Found
Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
ModelQuotePDFFreq
Min
(MHz)
Freq
Max
(MHz)
Gain
Min
(dB)
Gain
Flatness
(dB+/-)
Noise
Figure
(dB)
Noise
Temperature
(K)
Input
VSWR
Output
VSWR
P1dB
Out
(dBm)
IP3
Out
Typ
(dBm)
V1
Nom.
(V)
Curr1
Nom
(mA)
Outline
Drawing
Sort Ascending ModelSort Descending Model Sort Ascending PDFSort Descending PDFSort Ascending Freq<br>Min<br>(MHz)Sort Descending Freq<br>Min<br>(MHz)Sort Ascending Freq<br>Max<br>(MHz)Sort Descending Freq<br>Max<br>(MHz)Sort Ascending Gain<br>Min<br>(dB)Sort Descending Gain<br>Min<br>(dB)Sort Ascending Gain<br>Flatness<br>(dB+/-)Sort Descending Gain<br>Flatness<br>(dB+/-)Sort Ascending Noise<br>Figure<br>(dB)Sort Descending Noise<br>Figure<br>(dB)Sort Ascending Noise<br>Temperature<br>(K)Sort Descending Noise<br>Temperature<br>(K)Sort Ascending Input<br>VSWRSort Descending Input<br>VSWRSort Ascending Output<br>VSWRSort Descending Output<br>VSWRSort Ascending P1dB<br>Out<br>(dBm)Sort Descending P1dB<br>Out<br>(dBm)Sort Ascending IP3<br>Out<br>Typ<br>(dBm)Sort Descending IP3<br>Out<br>Typ<br>(dBm)Sort Ascending V1<br>Nom.<br>(V)Sort Descending V1<br>Nom.<br>(V)Sort Ascending Curr1<br>Nom<br>(mA)Sort Descending Curr1<br>Nom<br>(mA)Sort Ascending Outline<br>DrawingSort Descending Outline<br>Drawing
AMFW-4F-14501550-16-15P-L-WR62G 14500155003011.61301.51.515-15250153243
LNA-40-01000200-30-25P 10002000402302225-15475121623
AMF-3D-25002600-95-25P 2500026000202.59.502.52.524-15600166644
AMFW-6F-20202120-120-P1-TC 2020021200540.5-1201.31.515-15- 
AMFW-6F-20202120-100-23P 20200212005011.3971001.31.523-15900171401
LNA-30-01000200-30-25P 10002000302302225-15425121622_3D
AFD2-010020-25PMITEQ-AFD.PDF10002000251.25443922253515350113427
AMFW-6F-20202120-100-17P-WP 20200212005711.2871001.31.517-15500148201
AFD3-010020-17PMITEQ-AFD.PDF10002000331.52.522622172715100113427
AMF-3F-01000200-10-15P 100020004021762215-15180121622
AFS3-01000200-25-27P-6 10002000321.52.522622273715350 
AMF-3F-01000200-10-15P-GW 100020004021762215-15250121622
AFS4-09501050-50-23P-4 950010500301562822233315225113384
AMFW-6F-20202120-120-P1-TC-LIG 2020021200540.5-1201.31.5152215200131596
AFSM2-01000200-16-20PMITEQ-AFSM.PDF100020002511.61302220301580133720
AMFK-1B-03000400-40-26P 3000400061402226-15400138212
AMF-4F-07000800-40-15P 7000800040144392215-15150131581
AFSM1-01000200-16-20PMITEQ-AFSM.PDF100020001311.613022203015150133720
AM-1682-1020MITEQ-AM-1682 SERIES.PDF10002000430.52.521422173415180179685
AFD1-010020-20PMITEQ-AFD.PDF10002000110.753.536022203015150109888
AMFW-6S-11701275-70-P2 11700127505010.939701.251.520-15160138966
AFS44-15701680-50-20P-4401-18_02.PDF1570016800582502.52.519-15400140941
AFD2-031042-25P-MPMITEQ-AFD_LN_MP.PDF310042002214.552822253515350110228
AFD3-031042-25P-MPMITEQ-AFD_LN_MP.PDF310042002214.552822253515- 
AFS2-00100120-40-25P-6-GW-TCAFS2-00100100-25-25P-6.PDF1001200241443922253515225113384
AMF-2F-00900200-24P-GW 9002000130.75-02224-15350122686
AFD3-031042-23P-SP 31004200221.254.552822233315350122987
AMFW-4F-14401560-130-P1-L-WR62M 14400155003111.6091301.51.5152515200 
AMFW-6S-03700480-30-A110F 37004800540.50.5361.51.323-15250125063
AMF-3F-08500960-30-20P 85009600201.532892220-15220131581
SAFS-17301840-18P-PM-R5 1730018400100.5-01.51.5183015400167398
AMF-7F-15701680-50-20P 1570016800582502.52.519-15400137139
AFS1-01240237-14-20P-4 12402370160.751.411122203015125113384
AMFW-7S-07250840-50-P2-CPR137G 72508400601.50.691501.51.7520-15300133174
AMFW-7S-07250840-55-GW-23P 725084006210.691551.51.523-15350138968
AMFW-6S-360480-55-P2-F-TRF-L 36004800500.50.754551.51.520-15425125063
AMFW-4F-14401560-90-P1-WR62M 14400156003011.174901.51.51525-250187533
SAFS4-VS1060284R3 11550127503010.9671.81.5525--203708
AFS3-00950215-10-15P-4 950215030117622152515150113384
SAFS4-CDES102551 144001560031.40.751.116851.51.51525--203708
AMFW-7S-03600480-60-P2 36004800601.5-602220-15400125063
AFS4-00950215-10-20P-6 9502150401217022203015350113384
AMFW-6S-07800900-60-P1-UG138 78009000480.5-601.61.615-15200127534
AFS42-09501075-60-15P-APM-42 9500107505016022152515270151239
AWS-4F-10951225-40-25P 1095012250331402225-15850154709
AMFW-6S-07100840-55-P1 710084005010.754551.51.515-15150138968
AMFW-7S-03400480-35-23P-GW-1 340048006010.5362223-15400125063
AMFW-7S-03400480-35-GW-P2 340048006510.536222023-400125063
AMFW-6S-03400480-35-P2 340048005010.5362220-15400125063
AMFW-7S-03400480-35-F-P2 340048006010.5362220-15400125063
Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37