Translate:

Model: DB0218HW2

Product Category:Mixer
DescriptionDouble Balanced Mixer - Ultra Broadband
Inputs
RF Frequency Min.2000 MHz
RF Frequency Max18000 MHz
RF VSWR Typ.1.5 Ratio RF = -10 dBm, LO = +18 dBm
LO Frequency Min.2000 MHz
LO Frequency Max.18000 MHz
LO Power Min.17 dBm
LO Power Max.20 dBm
LO Power Typ.18 dBm
LO VSWR Typ.1.5 Ratio LO = +18 dBm
Outputs
IF Frequency Minimum0 MHz 3 dB bandwidth
IF Frequency Maximum750 MHz 3 dB bandwidth
IF VSWR Typ.1.5 Ratio IF = -10 dBm, LO = +18 dBm
Transfer Characteristics
Conversion Loss Maximum9.5 dB IF = 100 MHz, LO = +18 dBm
Conversion Loss Typical7.5 dB IF = 100 MHz, LO = +18 dBm
LO to RF Isolation Min.22 dB
LO to RF Isolation Typ.30 dB
LO to IF Isolation Typ.20 dB
RF to IF Isolation Typ.30 dB
Input P1dB Typical12 dBm LO = +18 dBm
Input IP3 Typical22 dBm LO = +18 dBm
Single Sideband Noise Figure10 dB
Single Sideband Noise Figure Typ.8 dB
Mechanical
Outline Drawing118169
Environmental
Operating Temperature Min.-54 °C
Operating Temperature Max.85 °C
Storage Temperature Minimum-65 °C
Storage Temperature Maximum125 °C
Quality Assurance
Test Data Supplied At 25 Deg. C
Conversion Loss
LO to RF Isolation
Documents for
DB0218HW2

Datasheet:
MITEQ-DB0218 (PDF)


ECCN: EAR

RoHS Compliant: Yes
Similar Models
Return to: Mixers

Please review the product PDF which contains the full and complete specifications.
For conflicts between the information on this page and the product PDF, the product PDF takes precedence.

 
Narda-MITEQ · 435 Moreland Road · Hauppauge NY 11788 USA · 631-231-1700