ModelQuoteFreq
Min
(MHz)
Freq
Max
(MHz)
Gain
Min
(dB)
Gain
Flatness
(dB+/-)
Noise
Figure
(dB)
Noise
Temperature
(K)
Input
VSWR
Output
VSWR
P1dB
Out
(dBm)
IP3
Out
Typ
(dBm)
V1
Nom.
(V)
Curr1
Nom
(mA)
Outline
Drawing
Sort Ascending ModelSort Descending Model Sort Ascending Freq<br>Min<br>(MHz)Sort Descending Freq<br>Min<br>(MHz)Sort Ascending Freq<br>Max<br>(MHz)Sort Descending Freq<br>Max<br>(MHz)Sort Ascending Gain<br>Min<br>(dB)Sort Descending Gain<br>Min<br>(dB)Sort Ascending Gain<br>Flatness<br>(dB+/-)Sort Descending Gain<br>Flatness<br>(dB+/-)Sort Ascending Noise<br>Figure<br>(dB)Sort Descending Noise<br>Figure<br>(dB)Sort Ascending Noise<br>Temperature<br>(K)Sort Descending Noise<br>Temperature<br>(K)Sort Ascending Input<br>VSWRSort Descending Input<br>VSWRSort Ascending Output<br>VSWRSort Descending Output<br>VSWRSort Ascending P1dB<br>Out<br>(dBm)Sort Descending P1dB<br>Out<br>(dBm)Sort Ascending IP3<br>Out<br>Typ<br>(dBm)Sort Descending IP3<br>Out<br>Typ<br>(dBm)Sort Ascending V1<br>Nom.<br>(V)Sort Descending V1<br>Nom.<br>(V)Sort Ascending Curr1<br>Nom<br>(mA)Sort Descending Curr1<br>Nom<br>(mA)Sort Ascending Outline<br>DrawingSort Descending Outline<br>Drawing
AFS1-00950145-50-10P-49501450180.556281.51.510201280113384
AFS2-07250775-50-0P-272507750200.5501.51.50-1250 
JS2-04000450-09-5P-GW40004500280.50.90225-15200 
AFS2-07250775-20-0P-4-12V72507750200.5201.51.50-1270 
AFD2-020025-08200025003510.802210-15250109962
AMF-3F-12201270-14-10P-GW1220012700220.251.41111.51.510-12100121622
AFS3-072507750-07-10P-4-BTO72507750300.50.701.51.510-15125 
SAFSW4-07250775-07-10P72507750400.50.65471.51.510-15-138966
AMFW-7F-19202020-1201970020200600.51.5041201.31.510-15225165402
AMF-5F-08000850-40-25P8000850040244392225-15750128871
AMF-2F-03050355-04-10P30503550281.30.5362213-15125131580
afs3-09000950-13-10p-4-l-tc90009500260.751.301.51.510-15150 
JPW5-07250775-60K-S725077505010.817601.251.35-1715150122637
AMF-4F-07250775-07-13P-TC-GW72507750400.50.7511.51.513-15175131581
AMF-4F-07250775-07-13P-S-WP72507750400.50.7511.51.513-15175207611
AFS4-01150165-07-0P-HE-BTO-SC11501650500.50.7511.51.5010450113384
AMF-4F-07250775-07-13P-BTO-S72507750400.50.7511.51.513-15175131581
AMF-4F-17501800-65-15P17500180002226.510062.22.215-15300128066
AFS3-09300980-15-10P-4-L-GW9300980032.50.51.5022102012150113384
AMF-2F-03100350-20-10P-TC-L3000350024121701.71.710-15125131580
AMF-5F-07250775-50K-13P-GW-TC72507750500.750.691501.251.513-15225131581
AMFW-6S-07250775-70K-TC-F-GW-172507750540.550.939701.251.510-15225173372
AMF-3F-09300980-13-12P-L93009800340.51.31022212-15125141132
AMF-3F-17501800-60-15P175001800022168652215-15200128066
AFD3-005010-LM50010003511.5022--15125113427
AFS3-07250775-07-S-4-R72507750300.50.7511.51.510201580113384
AMFW-7S-07900840-50-WR112G790084006010.691501.51.510-15200173372
AMFW-6F-31803230-25-8P31800323003512.5226228-15200129533
AMFW-7S-07250775-40-P2725077506010.561401.251.520-15250138968
AMF-3F-16001650-16-10P-TC1600016500230.51.61301.81.810-15-121622
AMFW-6S-07250775-45-P1-WR112G725077505010.691451.31.515-15200173372
AMF-3F-05400590-09-13P-L-GW-R540059002810.9671.51.513-15-121622
SAFS5-09100960-09-15P-S1-EM91009600390.21.41111.31.315-8175134794
AFSX3-02000250-10-10P-4-BTO20002500340.51761.81.810-15150141108
AFS2-00500100-15-10P-250010002511.512022102015125113384
AMFW-6S-07250775-45-TRF-S-N725077505010.626451.251.515-15300135805
SAFS4-01150165-07-0P-6-FM11501650500.50.7511.51.5010460113384
AMFW-3F-12201270-10-15P-APM122001270020-101.51.50-1270191123
AMF-3F-00500100-15-10P-TC-APM5001000451.51.502.12.110-15200132513
SAFS5-06900740-08-0P-6-EM69007400400.51.1841.51.50-555113384
SAFS5-06900740-08-0P-6-FM69007400400.51.1841.51.50-555113384
AMF-3B-05400590-60-27P54005900251-02227-151000145393
AFS4-02000250-12-10P-6-L20002500401.51.27622102015250113384
AMF-3f-07900840-09-10P79008400340.50.901.51.510-15200131581
AMFW-6S-07250775-50K-10P-RSH4072507750---0------138968
AMF-4F-05000550-30-25P5400590030156282225-15375131581
AMF-4F-05000550-30-25P-TC50005500350.53022253515600131581
AMF-5F-13301380-30-20P-TC1330013800350.5302220-15450137139
AMF-3F-08000850-50-0P80008500240.530220-20100121622
SAFS2-06900740-08-5P-4-EM69007400200.51.2931.51.55-535113384